Inkcazo
I-ZW32 i-Auto recloser luhlobo olukhethekileyo lwe-breaker circuit yombane eyenzelwe ukuvula nokuvala ngokukhawuleza. Ngokungafaniyo nabaphuli beesekethe, ezenzelwe ukuba "bahambe" kwaye bahlale kwindawo evulekileyo, inokutshintsha ngokukhawuleza amazwe ukusuka ekuvaleni, ukuvula nokubuya. Ezi zixhobo zijolise ekumiseni iimpazamo zenethiwekhi ekubangeleni ukuphuma kwexesha elide, ngokubuyisela ngokukhawuleza amandla.
I-auto recloser kukulungelelaniswa okuzenzekelayo kwe-breaker circuit ukuvala emva kokuvulwa ngenxa yokusebenza kokukhusela. Isetyenziswa kuzo zombini ukuhanjiswa kwe-Medium Voltage kunye ne-High Voltage Transmission, nangona ngeendlela ezahlukileyo kancinci. Ukusabalalisa i-VCB isebenzisa i-standalone auto reclosers, njenge-Recloser imveliso, enenkqubo yokulawula edibeneyo, i-HV Reclosing Circuit Breaker kunye ne-Remote SCADA FTU.
Lutshintsho olude lwe-vacuum yobomi obubonelela ngobomi bokusebenza obungaphezulu kwe-100,000 (i-30,000 evulekileyo / evaliweyo) yemisebenzi yolondolozo-simahla. Sebenzisa i-auto recloser yethu i-ZW32 iya kukhokelela kugcino olukhulu ekugcinweni okucuthiweyo kunye nexesha elongeziweyo lebhanki kwaye iya kuphucula umgangatho wamandla. Ihambelana nemigangatho ye-ANSIC37.66 kunye nemigangatho yaseTshayina. Uluhlu lwamandla ombane olulinganisiweyo 33KV 35KV 36KV 40.5KV. Inohlobo lwentwasahlobo oluhamba ngemoto kunye ne-actuator yamagnetic (enebhokisi yokulawula).
◆ Sebenzisa imiqathango
1.Ubushushu be-Ambient: -30℃~+60℃;
2.Ukuphakama: ≤3000m;
3.Isantya somoya: ≤34m/s;
4.Ibakala longcoliseko: ≤IV.
5.Storage lobushushu: -40℃~+85℃.
◆ IiParameters ezingundoqo zobuGcisa
HAYI. | Izinto | Iyunithi | Ixabiso |
1 | umbane olinganisiweyo | kV | 40.5 |
2 | Imizuzu eyi-1 yokumelana nombane | kV | 95 |
3 | Impembelelo yombane imelana nombane | kV | 185 |
4 | ireyithwe rhoqo | Hz | 50 |
5 | irethiwe yangoku | A | 630,1250,1600 |
6 | ireyithwe kwisekethe emfutshane yokwaphulwa kwangoku | kA | 20, 25, 31.5 |
7 | Ilinganiswe kwisekethe emfutshane yokwenza yangoku (incopho) | kA | 50, 63, 80 |
8 | Incopho elinganisiweyo ukumelana yangoku | kA | 50, 63, 80 |
9 | 4s ukumelana okwangoku | kA | 20, 25, 31.5 |
10 | ulandelelwano lokusebenza rated | S | O-0.1s-CO-3s-CO-6S-60s recovery |
11 | ireyithwe kwisekethe emfutshane yangoku inombolo yokwaphula | amaxesha | 30 |
12 | ubomi bomatshini | amaxesha | 10000 |
13 | Umbane wolawulo lwesixhobo | IN | AC/DC220 |
14 | isekethe yesibini 1min amandla frequency ukumelana nombane | kV | 2 |
15 | umgama wokucoca phakathi kwabafowunelwa abavulekileyo | mm | 16±1 |
16 | ngokuhamba | mm | 4±0.5 |
17 | isantya sokuvula | Nksk | 1.4-1.8 |
18 | isantya sokuvala | Nksk | 0.4-0.8 |
19 | ixesha lokuqhawula uqhagamshelwano lokuvala | Nksk | ≤5 |
20 | Isigaba sesithathu sokuvula/ukuvala iasynchronism | Nksk | ≤2 |
amashumi amabini ananye | ixesha lokuvala | Nksk | ≤100 |
amashumi anambini | ixesha lokuvula | Nksk | ≤50 |
amashumi amabini anantathu | ubunzima | ikg | 270 |