IThengiso elishushu le-36kv/630A iMv Draw-out Uhlobo lwe-Air Insulated Metal Clad Switchgear (KYN61)

Inkcazelo emfutshane:


Iinkcukacha zeMveliso

Iithegi zeMveliso

Qwalasela “uMthengi kuqala, uMgangatho kuqala” engqondweni, sisebenza ngokusondeleyo nabathengi bethu kwaye sibabonelele ngeenkonzo ezisebenzayo nezichubekileyo zokuThengisa okushushu kwe36kv/630A Mv Draw-out Type Air Insulated Metal Clad Switchgear (KYN61), Sithemba ngokunyanisekileyo ukuba seka unxulumano olwanelisayo kunye nawe ukusuka kufutshane ukuya kwixesha elide. Siza kukugcina unolwazi ngenkqubela yethu kwaye sihlale sixhasa ukwakha ubudlelwane obuzinzileyo kunye nawe.
Qwalasela “uMthengi kuqala, uMgangatho kuqala” engqondweni, sisebenza ngokusondeleyo nabathengi bethu kwaye sibabonelele ngeenkonzo ezifanelekileyo nezisebenzayoIsixhobo sokutshintsha esikwaziyo ukurhoxiswa somoya , Wamkele nayiphi na imibuzo yakho kunye neenkxalabo malunga neemveliso zethu. Sijonge phambili ekusekeni ubudlelwane beshishini bexesha elide nawe kungekudala. Qhagamshelana nathi namhlanje. Siliqabane lokuqala leshishini lakho!
Ngokubanzi
I-KYN61-40.5 uhlobo lwentsimbi ehoxisiweyo olurhoxisa uhlobo lwe-AC lwentsimbi evaliweyo (emva koku lubizwa ngokuba yi "switchgear") luphawulwa ikakhulu kusetyenziso lwe-ZN85-40.5 i-vacuum efakwe ngokupheleleyo i-vacuum breakers kunye neendlela zokusebenza zasentwasahlobo kwikhabhathi, kunye nomzimba wekhabhathi. ihlanganiswe ngentsimbi ehlanganiswe ngeplastiki, ephucula ukuchaneka okufanayo kweVCB kunye nekhabhinethi. I-VCB kulula ukuyityhala kwaye ikhuphe kwaye inokutshintshana okunamandla kunye nenkangeleko entle, izisombululo ezipheleleyo, ukusetyenziswa okukhuselekileyo nokuthembekileyo.
Le mveliso isetyenziswa kwi-35kV yesigaba sesithathu se-AC 50Hz inkqubo yamandla. Isetyenziselwa ukufumana nokusasaza amandla ombane kwizityalo zamandla, izitishi kunye namagumbi okuhambisa amandla oshishino kunye nemigodi. Inolawulo, ukhuseleko kunye nemisebenzi yokubeka iliso. Le mveliso ihambelana nemigangatho: GB3906 "I-alternating-current metal-enclosed switchgear kunye ne-controlgear yombane olinganisiweyo ngaphezu kwe-3.6kV kwaye ukuya kuthi ga kunye nokubandakanya i-40.5kV", i-GB / T11022 "Iinkcukacha eziqhelekileyo ze-high-voltage switchgear kunye nemigangatho yokulawula", DL / I-T404 "I-alternating-current metal-enclosed switchgear kunye nesixhobo sokulawula umbane olinganisiweyo ngaphezu kwe-3.6kV kunye nokunyuka ukuya kunye nokubandakanya i-40.5kV", I-IEC60298 "I-AC yentsimbi efakwe kwi-switchgear kunye nesixhobo sokulawula umbane olinganisiweyo ngaphezu kwe-1 kV kwaye ukuya kuthi ga ku-52kV".

Imiqathango yokusetyenziswa eqhelekileyo
● Ubushushu bomoya okwi-Ambient: -15℃~+40℃.
● Iimeko zokufuma:
I-avareji yemihla ngemihla yokufuma okuhlobene: ≤95%, i-avareji yemihla ngemihla yoxinzelelo lomphunga wamanzi ≤2.2kPa.
Umyinge wenyanga wokufuma ozalanayo yi-90%, kwaye umyinge wenyanga woxinzelelo lomphunga wamanzi yi-1.8kPa.
● Ukuphakama: ≤4000m.
● Ubunzulu benyikima: ≤8 degrees.
● Umoya ojikelezileyo akufanele ungcoliswe yirhasi edlayo okanye etshayo, umphunga wamanzi, njl.
● Iindawo ezingenazo ukungcangcazela rhoqo.

Uhlobo lweNkcazelo

1

IiParameters eziphambili zobuGcisa

Into

Iyunithi

Ixabiso

Umbane olinganisiweyo

kV

40.5

Ikalwe ngoku Ikalwe ngoku yebhasi enkulu

A

630, 1250, 1600

Ireyithiwe yangoku ye-breaker circuit enezixhobo

A

630, 1250, 1600

Inqanaba le-insulation I-1min yamandla ombane wokumelana nombane: isigaba-ukuya-kwisigaba, isigaba-ukuya-emhlabeni / kubo bonke abafowunelwa abavulekileyo

kV

95/110

Impembelelo yombane imelana nombane (incopho):inqanaba ukuya kwisigaba, isigaba ukuya emhlabeni,/kubafowunelwa abavulekileyo

kV

185/215

Amandla ombane amelana nombane wesekethe encedisayo kunye nolawulo lwesekethe

V/1 min

2000

Ilinganiswe rhoqo

Hz

50

Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku

kA

20, 25, 31.5

Ilinganiswe ngexesha elifutshane lokumelana nobude bexesha langoku/elilinganiselweyo lesekethe emfutshane

kA/4s

20, 25, 31.5

Incopho elinganisiweyo ukumelana yangoku

kA

50, 63, 80

Ilinganiswe kwisekethe emfutshane yokwenza yangoku

kA

50, 63, 80

I-voltage elinganisiweyo yesekethe yolawulo

IN

DC110/220, AC110/220

Isidanga soKhuseleko Indawo ebiyelweyo yeswitchgear

IP4X

Ikhompatimenti (xa iingcango zivulwa)

IP2X

IiParameters eziphambili zobuGcisa

IiParameters zobuGcisa ze-ZN85-40.5 Uhlobo lwe-Circuit Breaker nge-Spring Operating Mechanism (Idityanisiwe)

Into

Iyunithi

Ixabiso

Umbane olinganisiweyo

kV

40.5

Ikalwe ngoku

A

630, 1250, 1600

Inqanaba le-insulation I-1min yamandla ombane wokumelana nombane: isigaba-ukuya-kwisigaba, isigaba-ukuya-emhlabeni / kubo bonke abafowunelwa abavulekileyo

kV

95/110

Impembelelo yombane imelana nombane (incopho):inqanaba ukuya kwisigaba, isigaba ukuya emhlabeni,/kubafowunelwa abavulekileyo

kV

185/215

Amandla ombane amelana nombane wesekethe encedisayo kunye nolawulo lwesekethe

V/1 min

2000

Ilinganiswe rhoqo

Hz

50

Ilinganiswe kwisekethe emfutshane yokwaphulwa kwangoku

kA

20, 25, 31.5

Ilinganiswe kwisekethe emfutshane yokwenza yangoku

kA

50, 63, 80

Incopho elinganisiweyo ukumelana yangoku

kA

50, 63, 80

Ilinganiswe ngexesha elifutshane lokumelana nobude bexesha langoku/elilinganiselweyo lesekethe emfutshane

kA/4s

20, 25, 31.5

Ubomi bomatshini

amaxesha

1000

Ixesha lokuvala

Nksk

50~100

Ixesha lokuvula

Nksk

35~60

Ulandelelwano lokusebenza olukalwe

O-0.3s-CO-180s-CO

Ulwakhiwo
Le mveliso ihlulwe ibe ngamacandelo amabini: ikhabhinethi kunye neVCB. Ikhabhinethi yenziwe ngeplate yensimbi egobileyo kwaye ihlanganiswe kunye neebholiti emva kokutshiza. Ngokutsho kweempawu zokusebenza, inokwahlulwa ibe ngamacandelo amane: igumbi lebhasi elincinci, igumbi lesixhobo sokudlulisa, igumbi leVCB, igumbi lekhebula kunye negumbi lebhasi, inxalenye nganye ihlukaniswe yintsimbi yentsimbi. Iqondo lokhuseleko lwe-switchgear enclosure yi-IP4X; xa umnyango wegumbi leVCB uvulwa, idigri yokukhusela IP2X.

I-switchgear inezicwangciso eziphambili zesekethe ezifana ne-cable inlet kunye ne-outlet, i-inlet kunye ne-outlet engaphezulu, uqhagamshelo lwebhasi, ukuqhawula, i-voltage transformer, kunye nokubamba umbane. I-busbar ithatha i-insulation composite, kwaye i-inter-phase kunye neziqhagamshelo zixhotyiswe ngemikhono ekhuselayo eyenziwe ngezinto ezinqanda umlilo. Iikhabhinethi ezikufutshane ze-busbar eziphambili zihlukaniswe yimikhono ye-busbar, enokuthintela ngokufanelekileyo ingozi ukuba isasazeke kwaye idlale indima yokuncedisa kwi-busbar enkulu. Igumbi lekhebula lixhotyiswe ngenguqu yomhlaba, isixhobo sokukhusela i-overvoltage, njl.

Kukho i-shutter yentsimbi yokhuseleko phambi kwebhokisi yoqhagamshelwano. I-shutter ephezulu kunye nesezantsi yokhuseleko ivulwa ngokuzenzekelayo xa i-VCB isuka kwindawo yokuqhawula / yokuvavanya ukuya kwindawo yokusebenza, kwaye ivalwe ngokuzenzekelayo xa i-VCB ihamba kwicala elichaseneyo, ngokufanelekileyo ukukhupha kwi-voltage ephezulu. Ukudibanisa phakathi kokutshintsha okuphambili, i-VCB, ukutshintsha komhlaba kunye nomnyango wekhabhinethi ithatha indlela enyanzelekileyo yokudibanisa i-mechanical interlocking ukuhlangabezana neemfuno zokusebenza "zokuthintela ezintlanu".

I-breaker circuit ithatha i-screw rod drive propulsion mechanism kunye ne-clutch overrunning. Indlela yokutya ye-screw rod nut inokusetyenzwa ngokulula ukuhambisa i-VCB phakathi kwendawo yovavanyo kunye nendawo yokusebenza. Ngoncedo lwepropathi yokuzivalela ye-screw rod nut, i-VCB inokutshixwa ngokuthembekileyo kwindawo yokusebenza ukukhusela i-VCB kwingozi ebangelwa ukubaleka ngenxa yamandla ombane. I-clutch yokugqithisa isebenza xa i-VCB ibuyela kwindawo yokuvavanya kwaye xa ifikelela kwindawo yokusebenza. Yenza i-shaft yokusebenza kunye ne-screw shaft ikhuphe ngokuzenzekelayo kwaye ingasebenzi, enokuthi ithintele i-misoperation kwaye yonakalise indlela yokutya. Ezinye ii-VCBs zisebenzisa i-lever feed mechanism. Indawo yomsebenzi wokuvavanya ivaliwe ngokubeka izikhonkwane.
Imilinganiselo epheleleyo yekhabhinethi yile: W×D ×H (mm): 1400×2800×2600

1

Imizobo yeNkqubo yeSekethe ePhambili

Iskimu sokuqala NO.

1

2

3

4

5

Idayagram yesikimu sesekethe engundoqo

 1  2  3  4  5
Amacandelo esekethe engundoqo I-vacuum circuit breaker ZN85-40.5 1

1

1

1

1

I-transformer yangoku i-LZZBJ9-35

1-3

1-3

4-6

I-voltage transformer JDZ9-35
Ukubanjwa HY5WZ2

I-0 okanye i-3 ngokuzithandela

Ukutshintshela umhlaba JN24-40.5

0-1 ngokukhetha

Umboniso ohlawuliweyo

0-1 ungazikhethela

Fuse XRNP-35
Isiguquli samandla i-SC9-35
Isicelo

I-Overhead inlet (i-outlet)

I-KYN61-40.5 uhlobo lwesinyithi olunentsimbi olurhoxisa uhlobo lwe-AC olufakwe kwintsimbi (emva koku lubizwa ngokuba yi-"switchgear") luphawulwa ikakhulu kusetyenziso lwe-ZN85-40.5 i-vacuum efakwe ngokupheleleyo i-vacuum breakers kunye neendlela zokusebenza zasentwasahlobo kwikhabhinethi, kunye nomzimba wekhabhathi. ihlanganiswe ngentsimbi ehlanganiswe ngeplastiki, ephucula ukuchaneka okuhambelanayo kweVCB kunye nekhabhinethi. I-VCB kulula ukuyityhala kwaye ikhuphe kwaye inokutshintshana okunamandla kunye nenkangeleko entle, izisombululo ezipheleleyo, ukusetyenziswa okukhuselekileyo nokuthembekileyo.
Le mveliso isetyenziswa kwi-35kV yesigaba sesithathu se-AC 50Hz inkqubo yamandla. Isetyenziselwa ukufumana nokusasaza amandla ombane kwizityalo zamandla, izitishi kunye namagumbi okuhambisa amandla oshishino kunye nemigodi. Inolawulo, ukhuseleko kunye nemisebenzi yokubeka iliso. Le mveliso ihambelana nemigangatho: GB3906 ″Isixhobo sokutshintsha intsimbi yangoku kunye nesixhobo sokulawula samandla ombane alinganiswe ngaphezulu kwe-3.6kV ukuya kuthi ga kunye nokubandakanya i-40.5kV, i-GB/T11022 I-T404 "I-alternating-current metal-enclosed switchgear kunye nesixhobo sokulawula umbane olinganisiweyo ngaphezu kwe-3.6kV kunye nokunyuka ukuya kunye nokubandakanya i-40.5kV", I-IEC60298 "I-AC yentsimbi efakwe kwi-switchgear kunye nesixhobo sokulawula umbane olinganisiweyo ngaphezu kwe-1 kV kwaye ukuya kuthi ga ku-52kV".


  • Ngaphambili:
  • Okulandelayo: